* Added WUT 57606,57613,57720
* Added os wut-*
* fixed MIB Names and try to generalize wut
* more general sysObjectID mapping, and mib directory
* Delete WUT-57606-MIB
* Delete WUT-57613-MIB
* Delete WUT-57720-MIB
* Rename wut-57613.snmprec to wut_57613.snmprec
* Rename wut-57720.snmprec to wut_57720.snmprec
* Rename wut-57606.snmprec to wut_57606.snmprec
* Delete wut-57606.yaml
* Delete wut-57720.yaml
* Delete wut-57613.yaml
* Delete wut-57606.yaml
* Delete wut-57720.yaml
* Delete wut-57613.yaml
* Update wut.yaml
* Try to correct the Temperature part
This should work for temperature, according to MIB. Pressure and Humidity are not described in this mibfile, so we cannot poll them.
* change wut.yaml
* Add and fix wut_57720
* after ./scripts/save-test-data.php ?
* Add test data
Co-authored-by: PipoCanaja <[email protected]>
* Migrate ironware sensor discovery from php to yaml.
* More sensors, add grouping.
* dynamic_discovery_get_value() becomes getValueFromData()
* Target a specific index with skip_values.
* Improve Brocade BGP session discovery/polling
This commit allows for the correct discovery of BGP sessions
with 32-bit ASNs, IPv6 neighbors using the BGP4V2-MIB which is
based on draft-ietf-idr-bgp4-mibv2-11 and also polls for IPv4
unicast received routes through the FOUNDRY-SN-BGP4-GROUP-MIB.
Copied most of the code from PR#8877 by @Mikeburke14, cleaned
up the code a little bit to match the normal LibreNMS style,
and fixed bgpPeers_cbgp discovery as well as polling for the
ipv4.unicast neighbors.
Note that older Brocade IronWare firmware versions are known
to have multiple defects relating to the BGP4V2-MIB which
might result in certain missing non-established neighbors.
Related vendor defect numbers:
- DEFECT000633962
-- Symptom: The OID bgp4V2PeerAdminStatus does not return the
correct value
-- Reported: NI 05.7.00
-- Resolved: NI 05.8.00g
- DEFECT000583319
-- Symptom: SNMP polling on bgp4V2PeerTable (OID brcdIp.3.5.1.1.2)
does not display all the BGP entries
-- Reported: NI 05.6.00
-- Resolved: NI 05.8.00e
- DEFECT000550309
-- Symptom: SNMP polling on bgp4V2PeerTable (OID brcdIp.3.5.1.1.2)
does not display the full information
-- Reported: NI 05.7.00
-- Resolved: NI 05.8.00c
* Add ironware CER & ICX platform test data.
* Re-add ironware.json compatible with current master branch.
* Fix Air Fiber port stats
Define OS port polling includes in a standard way.
Move Air Fiber code to os port polling include.
* Update snmp data
* fix accidental change
* Some formatting fixes
* should be null
* Added definition and sensors for SIAE Alfoplus80HD
* updated the units for the wireless rate sensor
* Added test data
* regenerated test data as requested by PipoCanaja
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Updated test data for arubaos, fs-switch, ifotec, lcos, siklu and trendnet, to pass Travis tests
* Updated test data for arubaos, fs-switch, ifotec, lcos, siklu and trendnet, to pass Travis tests
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Add bad_ifoperstatus for filtering interfaces having a status for example notPresent
* Update nios.yaml
I tried to pull them all in using {{ index }}, but it didn't actually work.....
This adds the DHCP, DNS and NTP service statuses.
* Dynamic service discovery
* typo
* Create nios_status.snmprec
* Create nios_status.json
* Array
* Typo, more
Co-authored-by: PipoCanaja <[email protected]>
* Fix Siklu Voltage
* Update tests
* Another test fix attempt
* Decimals..
* Ok, enough.
* Restore currently used index value and correctly push num_oid
* Update siklu.json
Co-authored-by: PipoCanaja <[email protected]>
* Add version match for newer IOS-XR NCS hardware
* Tested with NCS-5504 and NCS5508
Signed-off-by: Misha Komarovskiy <[email protected]>
* Add test data for Cisco NCS-5504 and NCS-5508
Signed-off-by: Misha Komarovskiy <[email protected]>
* extend FS switches support
* MIB compilation
* HW and Ver
* sensors and CPU
* tests
* correct version
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to replace "down" with "not up" :)
* fix other ifOperStatus checks
* Initial stab at switch input state sensor
* Fix indentions
* Fix indentions
* Index updates
* More useless changes.
* And it finally works.
* Open should be a WARNING state.
* Update email
* Add line
* One empty line, not three.
* This is getting ridic.
* Add test data
* Add support for TRENDnet switch, TEG-S80ES in particular
* Add trendnet.snmprec
* Add test data (JSON)
* Remove mib comment from yaml
* Update copyright info
* Use sysDescr value for Hardware
* update nokia mibs
* database migrations
* add code
* html code
* update db schema
* add test data
* add FIXME
* move mibs/nokia/MPLS-TE-MIB to mibs/MPLS-TE-MIB
* - update yzyxel mibs
- update definitions für ies series
- slot state and alarm support via yaml
* more sensors
* add new device Zyxel IES4206
* restore original ies files
* revert function stuff
* update to latest official mib
* rebase
* Added Model number detection to old 3Com SWitches
* Added test data
* Added better way to obtain data from Old 3Com StackSwitches
* Removed debug prints
* Added needed mibs
* Removed mibs and changed to oid in script
* Added Original 3com mibs from http://oidref.com/static/mibdepot/*
* Create 3com_4200.json